16 research outputs found

    Image quality evaluation in X-ray medical imaging based on Thiel embalmed human cadavers

    Get PDF

    Correlation of clinical and physical-technical image quality in chest CT : a human cadaver study applied on iterative reconstruction

    Get PDF
    Background: The first aim of this study was to evaluate the correlation between clinical and physical-technical image quality applied to different strengths of iterative reconstruction in chest CT images using Thiel cadaver acquisitions and Catphan images. The second aim was to determine the potential dose reduction of iterative reconstruction compared to conventional filtered back projection based on different clinical and physical-technical image quality parameters. Methods: Clinical image quality was assessed using three Thiel embalmed human cadavers. A Catphan phantom was used to assess physical-technical image quality parameters such as noise, contrast-detail and contrast-to-noise ratio (CNR). Both Catphan and chest Thiel CT images were acquired on a multislice CT scanner at 120 kVp and 0.9 pitch. Six different refmAs settings were applied (12, 30, 60, 90, 120 and 150refmAs) and each scan was reconstructed using filtered back projection (FBP) and iterative reconstruction (SAFIRE) algorithms (1,3 and 5 strengths) using a sharp kernel, resulting in 24 image series. Four radiologists assessed the clinical image quality, using a visual grading analysis (VGA) technique based on the European Quality Criteria for Chest CT. Results: Correlation coefficients between clinical and physical-technical image quality varied from 0.88 to 0.92, depending on the selected physical-technical parameter. Depending on the strength of SAFIRE, the potential dose reduction based on noise, CNR and the inverse image quality figure (IQF(inv)) varied from 14.0 to 67.8 %, 16.0 to 71.5 % and 22.7 to 50.6 % respectively. Potential dose reduction based on clinical image quality varied from 27 to 37.4 %, depending on the strength of SAFIRE. Conclusion: Our results demonstrate that noise assessments in a uniform phantom overestimate the potential dose reduction for the SAFIRE IR algorithm. Since the IQF(inv) based dose reduction is quite consistent with the clinical based dose reduction, an optimised contrast-detail phantom could improve the use of contrast-detail analysis for image quality assessment in chest CT imaging. In conclusion, one should be cautious to evaluate the performance of CT equipment taking into account only physical-technical parameters as noise and CNR, as this might give an incomplete representation of the actual clinical image quality performance

    Wild insect diversity increases inter-annual stability in global crop pollinator communities.

    Get PDF
    While an increasing number of studies indicate that range, diversity and abundance of many wild pollinators has declined, the global area of pollinator-dependent crops has significantly increased over the last few decades. Crop pollination studies to date, have mainly focused on either identifying different guilds pollinating various crops, or on factors driving spatial changes and turnover observed in these communities. The mechanisms driving temporal stability for ecosystem functioning and services, however, remain poorly understood. Our study quantifies temporal variability observed in crop pollinators in 21 different crops across multiple years at a global scale. Using data from 43 studies from six continents, we show that (i) higher pollinator diversity confers greater inter-annual stability in pollinator communities, (ii) temporal variation observed in pollinator abundance is primarily driven by the three most dominant species, and (iii) crops in tropical regions demonstrate higher inter-annual variability in pollinator species richness than crops in temperate regions. We highlight the importance of recognising wild pollinator diversity in agricultural landscapes to stabilize pollinator persistence across years to protect both biodiversity and crop pollination services. Short-term agricultural management practices aimed at dominant species for stabilising pollination services need to be considered alongside longer-term conservation goals focussed on maintaining and facilitating biodiversity to confer ecological stability

    A systematic review and meta-analysis on the radiation dose of computed tomography in hybrid nuclear medicine imaging

    No full text
    Background While diagnostic reference levels (DRLs) are well-established for the radiopharmaceutical part, published DRLs for the CT component of positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT) are limited. This systematic review and meta-analysis provides an overview of the different objectives of CT in hybrid imaging and summarizes reported CT dose values for the most common PET/CT and SPECT/CT examinations. Also, an overview of already proposed national DRLs is given. Methods A systematic literature search was performed to identify original articles reporting CT dose index volume (CTDIvol), dose-length product (DLP) and/or national DRLs for the most frequently performed PET/CT and/or SPECT/CT examinations. Data were grouped according to the clinical objective: diagnostic (D-CT), anatomical localisation (AL-CT) or attenuation correction (AC-CT) CT. Random-effects meta-analyses were conducted. Results Twenty-seven articles were identified of which twelve reported national DRLs. For brain and tumour PET/CT imaging, CTDIvol and DLP values were higher for a D-CT (brain: 26.7 mGy, 483 mGy cm; tumour: 8.8 mGy, 697 mGy cm) than for an AC/AL-CT (brain: 11.3 mGy, 216 mGy cm; tumour: 4.3 mGy, 419 mGy cm). Similar conclusions were found for bone and parathyroid SPECT/CT studies: D-CT (bone: 6.5 mGy, 339 mGy cm; parathyroid: 15.1 mGy, 347 mGy cm) results in higher doses than AL-CT (bone: 3.8 mGy, 156 mGy cm; parathyroid: 4.9 mGy, 166 mGy cm). For cardiac (AC-CT), mIBG/octreotide, thyroid and post-thyroid ablation (AC/AL-CT) SPECT/CT pooled mean CTDIvol (DLP) values were 1.8 mGy (33 mGy cm), 4.6 mGy (208 mGy cm), 3.1 mGy (105 mGy cm) and 4.6 mGy (145 mGy cm), respectively. For all examinations, high variability in nuclear medicine practice was observed. Conclusion The large variation in CT dose values and national DRLs highlights the need for optimisation in hybrid imaging and justifies the clinical implementation for nuclear medicine specific DRLs

    Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?

    No full text
    Metal artifacts may negatively affect radiologic assessment in the oral cavity. The aim of this study was to evaluate different metal artifact reduction techniques for metal artifacts induced by dental hardware in CT scans of the oral cavity. Clinical image quality was assessed using a Thiel-embalmed cadaver. A Catphan phantom and a polymethylmethacrylate (PMMA) phantom were used to evaluate physical-technical image quality parameters such as artifact area, artifact index (AI), and contrast detail (IQF(inv)). Metal cylinders were inserted in each phantom to create metal artifacts. CT images of both phantoms and the Thiel-embalmed cadaver were acquired on a multislice CT scanner using 80, 100, 120, and 140 kVp; model-based iterative reconstruction (Veo); and synthesized monochromatic keV images with and without metal artifact reduction software (MARs). Four radiologists assessed the clinical image quality, using an image criteria score (ICS). Significant influence of increasing kVp and the use of Veo was found on clinical image quality (p = 0.007 and p = 0.014, respectively). Application of MARs resulted in a smaller artifact area (p < 0.05). However, MARs reconstructed images resulted in lower ICS. Of all investigated techniques, Veo shows to be most promising, with a significant improvement of both the clinical and physical-technical image quality without adversely affecting contrast detail. MARs reconstruction in CT images of the oral cavity to reduce dental hardware metallic artifacts is not sufficient and may even adversely influence the image quality

    Nonelective surgery at night and in-hospital mortality : prospective observational data from the European Surgical Outcomes Study

    No full text
    BACKGROUND Evidence suggests that sleep deprivation associated with night-time working may adversely affect performance resulting in a reduction in the safety of surgery and anaesthesia. OBJECTIVE Our primary objective was to evaluate an association between nonelective night-time surgery and in-hospital mortality. We hypothesised that urgent surgery performed during the night was associated with higher in-hospital mortality and also an increase in the duration of hospital stay and the number of admissions to critical care. DESIGN A prospective cohort study. This is a secondary analysis of a large database related to perioperative care and outcome (European Surgical Outcome Study). SETTING Four hundred and ninety-eight hospitals in 28 European countries. PATIENTS Men and women older than 16 years who underwent nonelective, noncardiac surgery were included according to time of the procedure. INTERVENTION None. MAIN OUTCOME MEASURES Primary outcome was in-hospital mortality; the secondary outcome was the duration of hospital stay and critical care admission. RESULTS Eleven thousand two hundred and ninety patients undergoing urgent surgery were included in the analysis with 636 in-hospital deaths (5.6%). Crude mortality odds ratios (ORs) increased sequentially from daytime [426 deaths (5.3%)] to evening [150 deaths (6.0%), OR 1.14; 95% confidence interval 0.94 to 1.38] to night-time [60 deaths (8.3%), OR 1.62; 95% confidence interval 1.22 to 2.14]. Following adjustment for confounding factors, surgery during the evening (OR 1.09; 95% confidence interval 0.91 to 1.31) and night (OR 1.20; 95% confidence interval 0.9 to 1.6) was not associated with an increased risk of postoperative death. Admittance rate to an ICU increased sequentially from daytime [891 (11.1%)], to evening [347 (13.8%)] to night time [149 (20.6%)]. CONCLUSION In patients undergoing nonelective urgent noncardiac surgery, in-hospital mortality was associated with well known risk factors related to patients and surgery, but we did not identify any relationship with the time of day at which the procedure was performed. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT0120360